FILE: TORUS1:[GLL_RAW.INFO]UVS_CMD_BYTES.DOC subtitle Command Byte Format ; -------------------------------------------------------------------------- ; |Byte/Bit| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ; |========+=======+=======+=======+=======+=======+=======+=======+=======| ; | Byte 1 | Even Science Frames Low Order Pointer | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 2 | Mode | F HV | N HV | G HV | Change| Motor | Don't | Don't | ; | | | Ovrd | Ovrd | Ovrd |Grating| Dir. | Care | Care | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 3 | F | N | G | HV Off| Stim | Limb | IP | IP | ; | |Channel|Channel|Channel| / ~On | Lamp | Ovrd | MSB | LSB | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 4 | Least Significant 8 Bits of Initial Position Delta | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 5 | Odd Science Frames Low Order Pointer | Byte 4| Byte 4| ; | | | MSB | MSB-1 | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 6 | 0 | 0 | 0 | 0 | 0 | Delta | Delta | Delta | ; | | | | | | | Sign | MSB | MSB-1 | ; |--------+-------+-------+-------+-------+-------+-------+-------+-------| ; | Byte 7 | Delta LSByte | ; -------------------------------------------------------------------------- ; Note: Delta Sign: 0 = Same Direction as previous scan ; 1 = Opposite Direction as previous scan Miniscan size table: cmd value size C1 1 C3 2 C5 3 C7 4 C9 6 CB 8 CD 11 CF 12 D1 16 D3 22 D5 24 D7 33 D9 44 DB 48 DD 66 DF 88 E1 132 E3 176 E5 264 E7 528