; file: /ansa4/euv/eng_monitors/how_to_read_eng.doc June 17, 2010 - kes ; the text files in this directory record the engineering monitors for one ; or both of the instruments. The 'E1' is shown in the text files and the ; list below is the key to what that monitor is recording. The values came ; from daily reports of these UVS/EUV monitors. ; ; What monitors were read was a function of the tables in the onboard ; computer; we did not always get the monitors we were interested in having. Page No. 1 EUV ENGINEERING MONITOR DATA FOR DAY 92-209 SOLAR DIST: 1.7767 AU 07/28/92 CHAN TEMP SENSOR DN TEMP Expected Expected DN Eng. Units E1- 3424 EUV +3Vdc Ref 255 3.01 255 3.008 E1- 3425 EUV 0Vdc Ref 0 0.01 0 5740E-6 E1- 3426 EUV LVPS Temp 159 24.72 53-235 -20 to +55 deg C E1- 3427 EUV +27Vdc Mon 187 29.06 185 28.75 E1- 3428 EUV +10Vdc Mon 179 9.87 178 9.817 E1- 3429 EUV +10Vdc Log Mon 215 10.12 214 10.07 E1- 3430 EUV Spec HV Mon# 169 1995.50 168 1984 E1- 3431 EUV Logic +10Vdc Mon 197 10.25 196 10.20 E1- 3432 EUV Logic +5Vdc Mon 217 5.17 217 5.158 E1- 3433 EUV Logic LVPS Temp 212 40.83 53-235 -20 to +55 deg C E1- 3434 HIC I/F Rel Temp 248 73.82 53-255 -20 to +85 deg C E1- 3435 EUV Logic Housing Temp 206 37.89 53-235 -20 to +55 deg C E1- 3436 EUV SPARE 0 0.01 0 5740E-6 E1- 3437 EUV Spec -10Vdc Mon 216 -11.96 216 -10.10 E1- 3438 EUV Spec -12Vdc Mon 207 -11.44 206 -11.38 E1- 3439 EUV Logic -10Vdc Mon 193 -10.66 191 -10.55 # Spectrometer HV value is given for Gain State 3 Galileo UVS Engineering Monitors CHAN SENSOR Lower Alarm Upper Alarm Limit Limit S-1793 UVS +10V 184 210 S-1794 UVS +5V 123 139 S-1798 UVS Logic Temp 053 208 S-1799 UVS Detect Temp 053 208 E-1790 UVS TC Temp 138 187 ; end-of-file