TORUS1:[GLL_RAW.INFO]UVS_FIDUCIAL.DOC UVS fiducial values should show up in packet#0 and packet #4 of each buffer dump. Each value is 2 bytes long and should be divided by (#RIMS)*7 to get the value per spectra. # definition expected value for IFL ------------------------------------------------------- 0-6 7 Sync words = FF hex 7 Starting Wavelength (~48 hex /3d hex) gg full scans ^ flyback on mf 0 8 UVS status byte # 1 3d hex bit(0=most signifigant bit) 0 F detector 0=off 1 N detector 0=off 2 G detector 1=on 3 F HV 1=off 4 N HV 1=off 5 G HV 1=off 6,7 Int. time 01=6msec 9 UVS status byte # 2 0c hex bit 0 mode 0=scan,1=fixed 1,2 wavelength 00 3 motor grating 0=same 4 micro 1=micro processor on 5 HV 1=hv off 6 stim lamp 0=off 7 limb sens. 0=off 10 Low Voltage (+10V) ~191 DN (range=184 - 210) 11 Low Voltage ( +5V) ~135 DN (range=123 - 139 12 High Voltage F-Channel ~25 DN =hv off,~127 DN=hv on,~78 = transition 13 High Voltage N-Channel ~25 DN =hv off,~127 DN=hv on,~78 = transition 14 High Voltage G-Channel ~25 DN =hv off,~127 DN=hv on,~78 = transition 15 Logic Temperature ?? 16 Detector Temperature ?? 17 Limb Sensor ~26 DN = nominal